LVDT Displacement and Position Sensors

LVDT Displacement Sensors Overview in Categories


Complete Overview LVDT Displacement and Position Sensors

LVDT-ISAL Displacement Sensor with unguided Armature
LVDT-ISAL Displacement Sensor with unguided Armature

LVDT-ISAL

Displacement Sensor with unguided Armature

Displacements: 2 / 5 / 10 / 20 / 50 / 100 / 200 mm
Output: mV/V (signal-conditioner necessary)
Housing
: Ø 20 mm
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient:  ±0,2 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: -35 .. +120 [°C]
Datasheet170015
STEP files: Download

LVDT-ISDL Displacement Sensor with unguided Armature and integrated Signal-Conditioner
LVDT-ISDL Displacement Sensor with unguided Armature and integrated Signal-Conditioner

LVDT-ISDL

Displacement Sensor with unguided Armature and integrated Signal-Conditioner

Displacement: 2 / 5 / 10 / 20 / 50 / 100 / 200 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: Ø 20 mm
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient:  ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: 0 .. +70 [°C]
Datasheet170016
STEP files: Download


LVDT-ISAL "KD" Displacement Sensor with Armature on both sides
LVDT-ISAL "KD" Displacement Sensor with Armature on both sides

LVDT-ISAL "KD"

Displacement Sensor with Armature on both sides

Displacement: 2 / 5 / 10 / 20 / 50 / 100 / 200 mm
Output: mV/V (signal-conditioner necessary)
Housing: Ø 20 mm
Armature: On both sides with core implementation on both sides for particularly dusty environmental conditions
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient:  ±0,2 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: -35 .. +120 [°C]
Datasheet170017
STEP files: Download

LVDT-ISDL "KD" Displacement Sensor with Core Implementation on both sides and Integrated Signal-Conditioner
LVDT-ISDL "KD" Displacement Sensor with Core Implementation on both sides and Integrated Signal-Conditioner

LVDT-ISDL "KD"

Displacement Sensor with Core Implementation on both sides and Integrated Signal-Conditioner

Displacements: 2 / 5 / 10 / 20 / 50 / 100 / 200 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: Ø 20 mm
Armature: On both sides with core implementation on both sides for particularly dusty environmental conditions
Rel. linearity error
: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient:  ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: 0 .. +70 [°C]
Datasheet170018
STEP files: Download


LVDT-ISAG Displacement Sensor with Swivel Heads and guided Armature
LVDT-ISAG Displacement Sensor with Swivel Heads and guided Armature

LVDT-ISAG

Displacement Sensor with Swivel Heads and guided Armature

Displacements: 2 / 5 / 10 / 20 / 50 / 100 / 200 mm (>200mm)
Output: mV/V (signal-conditioner necessary)
Housing: Ø 20 mm
Armature: Guided with plain bearing
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,2 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: -35 .. +120 [°C]
Datasheet: 170011
STEP files: Download

LVDT-ISDG Displacement Sensor with Joint Eyelet Fastening, guided Armature and integrated Signal-Conditioner
LVDT-ISDG Displacement Sensor with Joint Eyelet Fastening, guided Armature and integrated Signal-Conditioner

LVDT-ISDG

Displacement Sensor with Joint Eyelet Fastening, guided Armature and integrated Signal-Conditioner

Displacements: 2 / 5 / 10 / 20 / 50 / 100 / 200 mm (>200mm)
Output
: 0 .. 10 V / 4 .. 20 mA etc.
Housing: Ø 20 mm
Armature: Guided with plain bearing
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: 0 .. +70 [°C]
Datasheet170012
STEP files: Download


LVDT-ISAT Displacement Sensor with Spring Function
LVDT-ISAT Displacement Sensor with Spring Function

LVDT-ISAT

Displacement Sensor with Spring Function

Displacements: 2 / 5 / 10 / 20 / 50 mm
Output: mV/V (signal-conditioner necessary)
Housing: Ø 20 mm
Armature: Guided with spring function
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,2 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: -35 .. +120 [°C]
Datasheet170014
STEP files: Download

LVDT-ISDT Displacement Sensor with Spring Function and integrated Signal-Conditioner
LVDT-ISDT Displacement Sensor with Spring Function and integrated Signal-Conditioner

LVDT-ISDT

Displacement Sensor with Spring Function and integrated Signal-Conditioner

Displacements: 2 / 5 / 10 / 20 / 50 mm
Output
: 0 .. 10 V / 4 .. 20 mA etc.
Housing: Ø 20 mm
Armature: Guided with spring function
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient:  ±0,5 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: 0 .. +60 [°C]
Datasheet170013
STEP files: Download


LVDT-ISAP Displacement Sensor with Pneumatic Functional Armature and Spring
LVDT-ISAP Displacement Sensor with Pneumatic Functional Armature and Spring

LVDT-ISAP

Displacement Sensor with Pneumatic Functional Armature and Spring

Displacement: 10 / 20 / 50 mm
Output: mV/V (signal-conditioner necessary)
Housing: Ø 20 mm
Armature: Displacement sensor with pneumatic functional armature and spring
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,2 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -35 .. +120 [°C]
Datasheet170024
STEP files: Download

LVDT-ISDP Displacement Sensor with Pneumatic Functional Armature, Spring and Integrated Reading Converter
LVDT-ISDP Displacement Sensor with Pneumatic Functional Armature, Spring and Integrated Reading Converter

LVDT-ISDP

Displacement Sensor with Pneumatic Functional Armature, Spring and Integrated Reading Converter

Displacements: 10 / 20 / 50 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: Ø 20 mm
Armature: With pneumatic functional armature and spring
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient:  ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: 0 .. +70 [°C]
Datasheet170023
STEP files: Download


LVDT-IEDT Economy Displacement Sensor with Spring Function
LVDT-IEDT Economy Displacement Sensor with Spring Function

LVDT-IEDT

Economy Displacement Sensor with Spring Function

Displacements: 2 / 10 / 20 / 50 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: Ø 22 mm
Armature: Guided with spring function
Rel. linearity error: < ±0,75 [%F.S.]
Temperature coefficient: ±0,5 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: 0 .. +60 [°C]
Datasheet: 170009
STEP files: Download

LVDT-IEDL Economy Displacement Sensor with Unguided Armature
LVDT-IEDL Economy Displacement Sensor with Unguided Armature

LVDT-IEDL

Economy Displacement Sensor with Unguided Armature

Displacements: 2 / 10 / 20 / 50 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: Ø 22 mm
Armature: Unguided
Rel. linearity error: < ±0,75 [%F.S.]
Temperature coefficient:  ±0,5 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: 0 .. +60 [°C]
Datasheet170010
STEP files: Download


LVDT-IKAL Displacement Sensor - Armature with Linear Ball Bearing
LVDT-IKAL Displacement Sensor - Armature with Linear Ball Bearing

LVDT-IKAL

Displacement Sensor - Unguided armature

Displacements: 2 / 5 / 10 / 20 mm
Output: mV/V (signal-conditioner necessary)
Housing: Ø 8 mm
Armature: unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,5 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: -25 .. +85 [°C]
Datasheet170019
STEP files: Download

LVDT-IKAT Displacement Sensor - Guided Armature with Spring Function
LVDT-IKAT Displacement Sensor - Guided Armature with Spring Function

LVDT-IKAT

Displacement Sensor - Spring return

Displacements: 2 / 5 / 10 / 20 mm
Output: mV/V (signal-conditioner necessary)
Housing: Ø 8 mm
Armature: Spring return
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170020
STEP files: Download

LVDT-ILAT Displacement Sensor - Armature with mit Linear Ball Bearing and Spring Function
LVDT-ILAT Displacement Sensor - Armature with mit Linear Ball Bearing and Spring Function

LVDT-ILAT

Displacement Sensor - Spring return with linear ball bearing

Displacements: 2 / 5 / 10 mm
Output: mV/V (signal-conditioner necessary)
Housing: Ø 8 mm
Armature: Spring return with linear ball bearing
Rel. linearity error: < ±0,5 (±0,1) [%F.S.]
Temperature coefficient: ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: 0 .. +70 [°C]
Datasheet170021
STEP files: Download


LVDT-IZAL Miniature Displacement Sensor - Housing Ø 4 mm
LVDT-IZAL Miniature Displacement Sensor - Housing Ø 4 mm

LVDT-IZAL

Miniature Displacement Sensor - Housing Ø 4 mm

Displacements: 2 / 5 / 10 mm
Ouput: mV/V (signal-conditioner necessary)
Housing: Ø 4 mm
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,5 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: -25 .. +85 /°C]
Datasheet170022
Step files: Download


LVDT-IMAL Displacement Sensor with M12 External Thread and unguided Armature
LVDT-IMAL Displacement Sensor with M12 External Thread and unguided Armature

LVDT-IMAL

Displacement Sensor with M12 External Thread and unguided Armature

Displacements: 2 / 5 / 10 mm
Output
: mV/V (signal-conditioner necessary)
Housing: M12
Armature: unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170026
STEP files: Download

LVDT-IMDL Displacement Sensor with M12 External Thread, unguided Armature and integrated Signal-Conditioner
LVDT-IMDL Displacement Sensor with M12 External Thread, unguided Armature and integrated Signal-Conditioner

LVDT-IMDL

Displacement Sensor with M12 External Thread, unguided Armature and integrated Signal-Conditioner

Displacements: 2 / 5 / 10 / 20 mm
Output: 0 .. 10 V
Housing: M12
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170068
STEP files: Download


LVDT-IMAT Displacement Sensor with M12 External Thread and Spring Function
LVDT-IMAT Displacement Sensor with M12 External Thread and Spring Function

LVDT-IMAT

Displacement Sensor with M12 External Thread and Spring Function

Displacements: 2 / 5 / 10 / 20 / 50 mm
Output: mV/V (signal-conditioner necessary)
Housing: M12
Armature: Guided with Spring Function
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170025
STEP files: Download

LVDT-IMDT Displacement Sensor with M12 External Thread, Spring Function and integrated Signal-Conditioner
LVDT-IMDT Displacement Sensor with M12 External Thread, Spring Function and integrated Signal-Conditioner

LVDT-IMDT

Displacement Sensor with M12 External Thread, Spring Function and integrated Signal-Conditioner

Displacements: 2 / 5 / 10 / 20 / 50 mm
Output
: 0 .. 10 V
Housing: M12
Armature: Guided with spring function
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170067
STEP files: Download


LVDT-IGAL Displacement Sensor with M18 External Thread and unguided Armature
LVDT-IGAL Displacement Sensor with M18 External Thread and unguided Armature

LVDT-IGAL

Displacement Sensor with M18 External Thread and unguided Armature

Displacements: 2 / 5 / 10 / 20 / 50 mm
Output: mV/V (signal-conditioner necessary)
Housing: M18
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170028
STEP files: Download

LVDT-IGDL Displacement Sensor with M18 External Thread, unguided Armature and integrated Signal-Conditioner
LVDT-IGDL Displacement Sensor with M18 External Thread, unguided Armature and integrated Signal-Conditioner

LVDT-IGDL

Displacement Sensor with M18 External Thread, unguided Armature and integrated Signal-Conditioner

Displacements: 2 / 5 / 10 / 20 / 50 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: M18
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: 0 .. +70 [°C]
Datasheet170030
STEP files: Download


LVDT-IGAT Displacement Sensor with M18 External Thread and Spring Function
LVDT-IGAT Displacement Sensor with M18 External Thread and Spring Function

LVDT-IGAT

Displacement Sensor with M18 External Thread and Spring Function

Displacements: 2 / 5 / 10 / 20 mm
Output: mV/V (signal-conditioner necessary)
Housing: M18
Armature: Guided with spring function
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170027
STEP files: Download

LVDT-IGDT Displacement Sensor with M18 External Thread, Spring Function and integrated Signal-Conditioner
LVDT-IGDT Displacement Sensor with M18 External Thread, Spring Function and integrated Signal-Conditioner

LVDT-IGDT

Displacement Sensor with M18 External Thread, Spring Function and integrated Signal-Conditioner

Displacements: 2 / 5 / 10 / 20 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: M18
Armature: Guided with spring function
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170008
STEP files: Download


LVDT-IHDL-M16 Position control for hydraulic valves up to 400 bar pressure-resistant
LVDT-IHDL-M16 Position control for hydraulic valves up to 400 bar pressure-resistant

LVDT-IHDL-M16

Position control for hydraulic valves up to 400 bar pressure-resistant

Displacements: 6 / 32 / 36 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Mechanical connection: M16
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient:  ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: -25 .. +85 [°C]
Datasheet: 170069

LVDT-IHDZ Embedded Construction Version l for hydraulic valves up to 400 bar pressure-resistant
LVDT-IHDZ Embedded Construction Version l for hydraulic valves up to 400 bar pressure-resistant

LVDT-IHDZ

Embedded Construction Version l for hydraulic valves up to 400 bar pressure-resistant

Displacement: 2 .. 20 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Mechanical connection: Embedded construction
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: -25 .. +85 [°C]
Information: Productinfo

LVDT-IHDL Position control for hydraulic valves up to 400 bar pressure-resistant
LVDT-IHDL Position control for hydraulic valves up to 400 bar pressure-resistant

LVDT-IHDL

Position control for hydraulic valves up to 400 bar pressure-resistant

Displacements: 3 .. 20 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Mechanical connection: M12 / M16 / M20
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: -25 .. +85 [°C]
Information: Productinfo