LVDT with guided armature

The core including the core extension (armature) are working without contact

LVDT-ISAL Displacement Sensor with unguided Armature
LVDT-ISAL Displacement Sensor with unguided Armature

LVDT-ISAL

Displacement Sensor with unguided Armature

Displacements: 2 / 5 / 10 / 20 / 50 / 100 / 200 mm
Output: mV/V (signal-conditioner necessary)
Housing
: Ø 20 mm
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient:  ±0,2 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: -35 .. +120 [°C]
Datasheet170015
STEP files: On request

LVDT-ISDL Displacement Sensor with unguided Armature and integrated Signal-Conditioner
LVDT-ISDL Displacement Sensor with unguided Armature and integrated Signal-Conditioner

LVDT-ISDL

Displacement Sensor with unguided Armature and integrated Signal-Conditioner

Displacement: 2 / 5 / 10 / 20 / 50 / 100 / 200 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: Ø 20 mm
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient:  ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67, IP68)
Operation temperature range: 0 .. +70 [°C]
Datasheet170016
STEP files: On request


LVDT-IEDL Economy Displacement Sensor with Unguided Armature
LVDT-IEDL Economy Displacement Sensor with Unguided Armature

LVDT-IEDL

Economy Displacement Sensor with Unguided Armature

Displacements: 2 / 10 / 20 / 50 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: Ø 22 mm
Armature: Unguided
Rel. linearity error: < ±0,75 [%F.S.]
Temperature coefficient:  ±0,5 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: 0 .. +60 [°C]
Datasheet170010
STEP files: On request


LVDT-IZAL Miniature Displacement Sensor - Housing Ø 4 mm
LVDT-IZAL Miniature Displacement Sensor - Housing Ø 4 mm

LVDT-IZAL

Miniature Displacement Sensor - Housing Ø 4 mm

Displacements: 2 / 5 / 10 mm
Ouput: mV/V (signal-conditioner necessary)
Housing: Ø 4 mm
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: ±0,5 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: -25 .. +85 /°C]
Datasheet170022
Step files: On request


LVDT-IMDL Displacement Sensor with M12 External Thread, unguided Armature and integrated Signal-Conditioner
LVDT-IMDL Displacement Sensor with M12 External Thread, unguided Armature and integrated Signal-Conditioner

LVDT-IMDL

Displacement Sensor with M12 External Thread, unguided Armature and integrated Signal-Conditioner

Displacements: 2 / 5 / 10 / 20 mm
Output: 0 .. 10 V
Housing: M12
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170068
STEP files: On request

LVDT-IMAL Displacement Sensor with M12 External Thread and unguided Armature
LVDT-IMAL Displacement Sensor with M12 External Thread and unguided Armature

LVDT-IMAL

Displacement Sensor with M12 External Thread and unguided Armature

Displacements: 2 / 5 / 10 mm
Output
: mV/V (signal-conditioner necessary)
Housing: M12
Armature: unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170026
STEP files: On request


LVDT-IGAL Displacement Sensor with M18 External Thread and unguided Armature
LVDT-IGAL Displacement Sensor with M18 External Thread and unguided Armature

LVDT-IGAL

Displacement Sensor with M18 External Thread and unguided Armature

Displacements: 2 / 5 / 10 / 20 / 50 mm
Output: mV/V (signal-conditioner necessary)
Housing: M18
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: -25 .. +85 [°C]
Datasheet170028
STEP files: On request

LVDT-IGDL Displacement Sensor with M18 External Thread, unguided Armature and integrated Signal-Conditioner
LVDT-IGDL Displacement Sensor with M18 External Thread, unguided Armature and integrated Signal-Conditioner

LVDT-IGDL

Displacement Sensor with M18 External Thread, unguided Armature and integrated Signal-Conditioner

Displacements: 2 / 5 / 10 / 20 / 50 mm
Output: 0 .. 10 V / 4 .. 20 mA etc.
Housing: M18
Armature: Unguided
Rel. linearity error: < ±0,5 (±0,25) [%F.S.]
Temperature coefficient: < ±0,5 [%F.S./10K]
Degree of protection: IP65 (IP67)
Operation temperature range: 0 .. +70 [°C]
Datasheet170030
STEP files: On request