Complete Overview Force Sensors, Load Cells, Shear Beam

Exact force measurement and weight measurement

Force Sensors Overview in Categories

Complete Overview Force Sensors

Force Sensor FS55

Force Measurement in pressure direction, integrated Overload Protection

Force Direction: Push
Measuring Range: 2,5 kN
Output Signal: 1,5 ±2% [mV/V]
Linearity deviation: < ±0,1 [%F.S.]
Temperature Coefficient:  < 0,05 [%F.S./10K]
Degree of Protection: IP65
Operation temperature range: -20 .. +60 [°C]
Datasheet170038

Force Sensor KMM50

Force measurement in pressure direction up to 500 kN

Force Direction: Push
Measuring Range: 1 .. 500 kN
Output Signal: 1,5 ±2% [mV/V]
Linearity deviation: <0,2 .. <1 [%F.S.]
Temperature Coefficient:  < 0,02 [%F.S./10K]
Degree of Protection: IP64
Operation temperature range: -10 .. +70 [°C]
Datasheet170033

Force Sensor KMM60

Force Sensor with 4x90° Fastening Drilling

Force Direction: Push
Measuring Range: 0,5 .. 10 kN
Output Signal: 1,5 ±5% [mV/V]
Linearity deviation: <0,2 [%F.S.]
Temperature Coefficient:  <0,1[%F.S./10K]
Degree of Protection: IP54
Operation temperature range: -10 .. +70 [°C]
Datasheet170034

Force Sensor KMT55

Force Sensor with integrated Signal-Conditioner

Force Direction: Push
Measuring Range: 1 .. 500 kN
Output Signal: 0..10 V / 4..20mA uvm.
Linearity deviation: <0,5 [%F.S.]
Temperature Coeffizient:  <0,1 [%F.S./10K]
Degree of protection: IP54
Operation temperature range: 0 .. +60 [°C]
Datasheet170037

Force Sensor KMM20

Force Measurement Pull Push Direction

Force Direction: Pull / Push
Measurement Range: 0,1 .. 5 kN
Output Signal: 1/ 1,5 ±3% [mV/V]
Linearity deviation: <0,2 [%F.S.]
Temperature Coefficient:  < 0,1 [%F.S./10K]
Degree of protection: IP54
Operation temperature range: -10 .. +70 [°C]
Datasheet170031

Force Sensor KMM30

Force Measurement Pull Push Direction

Force Direction: Pull / Push
Measuring range: 0,1 .. 5 kN
Output signal: 1/ 1,5 ±3% [mV/V]
Linearity deviation: <0,2 [%F.S.]
Temperature Coefficient:  < 0,1 [%F.S./10K]
Degree of protection: IP54
Operation temperature range: -10 .. +70 [°C]
Datasheet170032

Force Sensor KMM62

Force Measurement Pull Push Direction

Force Direction: Pull / Push
Measuring range: 0,1 .. 0,5 kN
Output Signal: 1 ±2% [mV/V]
Linearity deviation: <0,2 [%F.S.]
Temperature Coefficient:  < 0,1 [%F.S./10K]
Degree of protection: IP54
Operation temperature range: -10 .. +70 [°C]
Datasheet170035

Force Sensor KMM65

Force Sensor with go-through drilling

Force Direction: Pull / Push
Measuring range: 1 .. 500 kN
Output Signal: 1,5 ±2% [mV/V]
Linearity deviation: <0,2 [%F.S.]
Temperature Coefficient:  < 0,1 [%F.S./10K]
Degree of protection: IP54
Operation temperature range: -10 .. +70 [°C]
Datasheet170036

Force Sensor FS50

Force Measurement Pull Push Direction

Force Direction: Pull / Push
Measuring range: 0,2 .. 200 kN
Output Signal: 2 [mV/V]
Linearity deviation: <0,1 [%F.S.]
Temperature Coefficient:  < 0,1 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: 0 .. +70 [°C]
Datasheet170039

Force Sensor FT50

Force Sensor with integrated Signal-Conditioner

Force Direction: Pull / Push
Measuring range: 0,5 .. 200 kN
Output Signal: 0..10 V / 4..20mA uvm.
Linearity deviation: <0,1 [%F.S.]
Temperature Coefficient:  <0,2 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: 0 .. +70 [°C]
Datasheet170040

Force Sensor FS05

S-Form Force Sensor with high overload protection

Force Direction: Pull / Push
Measuring range: 0,5 .. 10 kN
Output Signal: 2 ±10% [mV/V]
Linearity deviation: <0,1 [%F.S.]
Temperature Coefficient:  < 0,1 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: 0 .. +70 [°C]
Datasheet170045

Force Sensor FS06

S-Form Force Sensor with high accuracy

Force Direction: Pull / Push
Measuring range: 0,1 .. 5 kN
Output Signal: 2 ±0,05% [mV/V]
Linearity deviation: <0,02 [%F.S.]
Temperature Coefficient:  <0,02[%F.S./10K]
Degree of protection: IP64
Operation temperature range: -20 .. +60 [°C]
Datasheet170064

Force Sensor FS09

Miniature Force Sensor, small Measuring Range from 5 N

Force Direction: Pull / Push
Measuring range: 5 .. 20 N
Output Signal: 1 ±20% [mV/V]
Linearity deviation: <0,5 [%F.S.]
Temperature Coefficient:  < 0,5 [%F.S./10K]
Degree of protection: IP64
Operation temperature range: -20 .. +60 [°C]
Datasheet170046

Force Sensor FS10

S-Form Force Sensor up to 50 kN

Force Direction: Pull / Push
Measuring range: 1 .. 50 kN
Output Signal: 2 ±2% [mV/V]
Linearity deviation: <0,1 [%F.S.]
Temperature Coefficient:  < 0,15 [%F.S./10K]
Degree of protection: IP64
Operation temperature range: 0 .. +70 [°C]
Datasheet170041

Force Sensor FT10

S-Form Force Sensor up to 50 kN

Force Direction: Zug / Druck 
Measuring range: 1 .. 10 kN
Output Signal: 0 .. 10 V / 4 .. 20mA uvm.
Linearity deviation: <0,1 [%F.S.]
Temperature Coefficient:  < 0,15 [%F.S./10K]
Degree of protection: IP64
Operation temperature range: 0 .. +70 [°C]
Datasheet170042

Force Sensor FS12

Miniature Shear Beam Force Sensor

Force Direction: Pull / Push
Measuring range: 0,1 .. 0,2 kN
Output Signal: 2 ±15% [mV/V]
Linearity deviation: <0,25 [%F.S.]
Temperature Coefficient:  < 0,5 [%F.S./10K]
Degree of protection: IP65
Operation temperature range: -10 .. +70 [°C]
Datasheet170049

Force Sensor FS19

Shear Beam Force Sensor

Force Direction: Pull / Push
Measuring range: 1 .. 10 kN
Output Signal: 2 ±2% [mV/V]
Linearity deviation: <0,15 [%F.S.]
Temperature Coefficient:  < 0,1 [%F.S./10K]
Degree of protection: IP64
Operation temperature range: 0 .. +60 [°C]
Datasheet170047

Force Sensor FT19

Shear Beam Force Sensor with Signal-Conditioner

Force Direction: Pull / Push
Measuring range: 1 .. 10 kN
Output Signal: 0 .. 10 V / 4 .. 20mA uvm.
Linearity deviation: <0,15 [%F.S.]
Temperature Coefficient:  < 0,1 [%F.S./10K]
Degree of protection: IP64
Operation temperature range: 0 .. +60 [°C]
Datasheet170048